What was found
CRACKED RT CUSP WEB BS 500 BETWEEN X-54 TO X-60. HFEC INSPECTION ACCOMPLISHED, TWO CRACKS OF 0.250" AND 0.370" WERE FOUND IAW NDT SRM 06-10-01.001. A REPAIR WAS FABRICATED IAW SRM 53-05 FIG. 131A-10. DAMAGE WAS REMOVED IAW SRM 53-05, FIG 131A-10. AREA AND REPAIR WAS TREATED AND PAINTED IAW SRM 51-10-3, PAR 14, 21 DOUBLERS REPAIR INSTALLED IAW 51-30-5, & 51-30-1.