CORROSION ON LOWER SILL BETWEEN FRAME 66 TO FRAME 68 AND STR 23L AT AFT GALLEY AREA L=2.000", W=1.125", D=0.004". MEASSURES APPROXIMATELY, SSI 534147. REPLACED LOWER SILL LOCATED BETWEEN FRAME 66 TO FRAME 68 AT LEVEL STR 23L AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480505.