What was found
CRACKED INTERCOSTAL X=0 BETWEEN STA Y=1307 TO Y=1287 ALSO X=3 BETWEEN STA Y=1287 TO Y=1279 AT FLOOR STRUCTURE CABIN. SM, W2, CARD 301, ZONE 201. INTERCOSTAL WERE REMOVED IAW SRM 51-30-2, 51-30-5, NEW INTERCOSTAL STA: Y=1287-1307 WAS DRILLED IAW SRM 51-10-4. INTERCOSTAL STA= Y= 1287-1387 WAS DRILLED IAW SRM 51-10-4. INTERCOSTAL WAS TREATED AND PAINTED IAW SRM 51-10-3, PAR 21, 14. NEW INTERCOSTAL WAS INSTALLED IAW SRM 51-30-2. OUTFLOW VALVE CONTROL CABLE BRACKET WAS REMOVED IAW AMM 20-30-01-201. INTERCOSTAL WAS INSTALLED IAW SRM 51-30-5. DIMENSION CRACK STA Y= 1271-1307 IS 0.750 DIMENSION CRACK STA Y= 1271-1237 IS 1.500.