What was found
WEAR ON LT CUSP WEB BS Y=465 BETWEEN X=44 TO 54 AT PAX CABIN FLOOR STRUCTURE. WEAR WAS BLENDED OUT IAW SRM 53-01, FIG. 1 AND REPAIRED AREA SRM 53-05, FIG 131A-1 AND SRM 51-10-3, PAR 21 AND 14 NDT SPM 04-00-07, PAR 5, FIG 3, SHEET 1 AND 2 WAS ACCOMPLISHED ORIGINAL THICKNESS IS 0.020" AND REMAINING THICKNESS IS 0.010",THEREFORE, IS OUT OF LIMITS IAW ER/A 508307-14MA, REV. A.