What was found
LIGHTNING STRIKE ON LT FUSELAGE WINDOW BELT AFT EDGE BETWEEN BS Y=408 TO Y=427. LIGHTNING STRIKE ON LT FUSELAGE WINDOW BELT AFT EDGE BETWEEN BS Y=408 TO Y=427 WERE REPAIRED IAW ERA 536438-14, REV. ORIGINAL. ORIGINAL THICKNESS 0.086". REMAINING THICKNESS 0.094" ON AFT LWR CORNER AND ORIGINAL THICKNESS 0.094" AND REMAINING THICKNESS 0.087" ON FWD UPPER CORNER ON CRITICAL ZONE, SRM 53-05, FIG 111 ON NO CRITICAL ZONE. PERFORM DECAL CONDITION INSPECTION EVERY C-CHECK. RII COMPLETED.