What was found
LIGHTNING STRIKE ON FUSELAGE WINDOW BELT AFT UPPER CORNER BETWEEN BS Y=560 TO Y=579 AND STA Y=579 TO Y=598. LIGHTNING STIKE ON FUSELAGE WINDOW BELT AFT UPPER CORNER BS Y= 579 TO Y=598 IN REF. CARD 19, ZONE 100 WERE REPAIRED IAW ER/A 536451-14, REV ORIGINAL, WITH DIMENSIONS: ORIGINAL THICKNESS 0.11"/0.86" REMAINING THICKNESS 0.110"/0.080" UPPER CORNER, AND ON FWD UPPER CORNER ER/A 536450-14, REV ORIGINAL THICKNESS 0.105" REMAINING 0.098" TIME LIMITED. PERFORM DECAL CONDITION INSPECTION EVERY C-CHECK. RII COMPLETED.