What was found
CORROSION ON MAIN CABIN FLOOR STRUCTURE, CHANNEL ATTACHED TO BOX BEAM BETWEEN BS 720 AND BS 740, RBL 61 CP53-232-01I. R & R CHANNEL ATTACHED TO BOX BEAM BETWEEN BS 720 AND 740, RBL 61 IAW DWG 143N5400 AND SRM 51-40-02. REMOVED CORROSION IAW SRM 53-00-51, ORIGINAL.