What was found
CRACKED RT CUSP WEB BETWEEN BS X= -52 TO -55 AND Y= 905 TO 910. CUSP WEB WAS STOP DRILLED AND INSPECTION HFEC IAW SRM 51-01, PAR 21. FABRICATED DOUBLER OF REPAIR AND INSTALLED IAW SRM 53-05, FIGURE 131A-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED RT CUSP WEB BETWEEN BS X= -52 TO -55 AND Y= 905 TO 910. CUSP WEB WAS STOP DRILLED AND INSPECTION HFEC IAW SRM 51-01, PAR 21. FABRICATED DOUBLER OF REPAIR AND INSTALLED IAW SRM 53-05, FIGURE 131A-1.