What was found
UPON REMOVAL OF LT TRANSITION PANEL IN AFT CARGO ON NR 100-200 FOUND INTERCOSTAL UPPER ANGLE WITH CORROSION BETWEEN BS 1480-1500 ABOVE STR 26L. REMOVED CORROSION INTERCOSTAL UPPER ANGLE BETWEEN STA 1480-1500, STR 26L IAW SRM 53-00-04, FIG 101. MATERIAL ORIGINAL THICKNESS .050 MATERIAL LOSS .020 FOUND OUT OF LIMITS IAW SRM 53-00-04, FIG 101: DETAIL II REMOVED AND FABRICATED REPLACED "L" ANGLE INTERCOSTAL UPPER BETWEEN STA. 1480-1500, STR 26L IAW DWG 146N5340.