CORROSION ON UPPER/LOWER SURFACE RT CUSP WEB BETWEEN X=-54 TO X=-60 BS 503-588, DAMAGE FOUND BS 578 X -60 WILL BE ATTENDED WITH CARD 316, ZONE 201. DUE TO EXCESSIVE CORROSION ON BS 503 - 511 AND BS 544 - 553 WAS REPAIRED IAW SRM 53-05, 131A-11, AND SRM 53-05, FIG 131A-6.