What was found
CORROSION AND WEAR ON COUNTERSINK OF FUEL ACCESS PLATE 1303. THE ACCESS PANEL WAS FOUND OUT OF LIMITS IAW SRM 51-22-2A 6B AND REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AND WEAR ON COUNTERSINK OF FUEL ACCESS PLATE 1303. THE ACCESS PANEL WAS FOUND OUT OF LIMITS IAW SRM 51-22-2A 6B AND REPLACED.