What was found
CORROSION ON BS 345 FLOORBEAM UPPER TEE, BETWEEEN BL 0 AND LBL 20. BLENDED OUT CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01 ALLOWABLE DAMAGE 1, FIG 101, DETAIL III. CUT OUT THE DAMAGE SECTION BETWEEN RBL 35 TO LBL 50.5. FABRICATED A REPAIR, LOCATED, DRILLED, AND NDT HFEC SURFACE IAW NTM PT6 51-00-19 AND 51-00-16 IAW SRM 53-00-51, REP 10, PG 202. NO CRACKS.