What was found
DURING JACKSCREW INSPECTION, FOUND LT VERTICAL SUPPORT STRUCTURE CRACKED. REMOVED LT VERTICAL STABILIZER SUPPORT STRUCTURE, CLIP, REPLACEMENT CLIP WAS FABRICATED. DRILLED, PAINTED AND INSTALLED IAW DWG 9911808 AND SRM 51-30-04 AS A REF.