What was found
CORROSION ON WEB FRAME 16 STR 23L AT FWD GALLEY AREA. REPLACED WEB LOCATED AT FWD GALLEY AREA ON FRAME 16 AT LEVEL STR 23L IAW 51-72-11 SRM AND DWG 53112570.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON WEB FRAME 16 STR 23L AT FWD GALLEY AREA. REPLACED WEB LOCATED AT FWD GALLEY AREA ON FRAME 16 AT LEVEL STR 23L IAW 51-72-11 SRM AND DWG 53112570.