What was found
ELONGATED HOLES ON FUSELAGE SKIN UNDER REPAIR DOUBLER BETWEEN BS 800 - 810 LONGERON 28 - 30R. THE AREA WAS TRIMED, REPAIR FABRICATED, DRILLED, TRIMED, TREATED, PAINTED AND INSTALLED IAW SRM 51-30-5, SRM 53-04, SRM 51-10-4, AN DSRM 51-10-3, PAR 14 - 21.