What was found
LEFT WING INBD FLAP T/E WEDGE PANEL LOWER SURFACE IS DAMAGED, DENTED, PUNCTURED, AND CRACKED MF BS 223 TO MF BS 240. ACCOMPLISHED REPAIR OF THE DISCREPANT AREA ON LT WING INBD FLAP T/E WEDGE IAW SRM 51-70-10, TRIMOUT DIMENSION: 17" X 9.5". COMPLIED WITH ALL STEPS ON JIC 2034-8210-01.