What was found
CORROSION ON FLOOR SUPPORT, BS 332 - 336, RBL 3. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, AD1, FIG 101, DETAIL VI. R & R THE FLOOR SUPPORT IAW SRM 51-40-02, PAR 7D, PAGE 7 & DWG 141N5160.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT, BS 332 - 336, RBL 3. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, AD1, FIG 101, DETAIL VI. R & R THE FLOOR SUPPORT IAW SRM 51-40-02, PAR 7D, PAGE 7 & DWG 141N5160.