What was found
FREEPLAY AND CORROSION ON BUSHING OF CONTROL TAB ATTACH POINTS AT RT ELEVATOR. CONTROL TAB ATTACH POINTS WERE REPLACED IAW CMM 27-30-1. FITTING ON BS XET=48.293 WAS REMOVED IAW AMM 20-30-01-201 NEW FITTING WAS DRILLED, TREATED, PAINTED AND INSTALLED IAW SRM 51-10-4, 51-10-3 PAR 21 AND 14 AND 51-30-2.