What was found
CRACK ON FITTING AT BS 905 X -51 AND Z -2. ADJUSTED AND DRILLED NEW FITTING IAW DWG 3922286, REV D, SRM 51-10-4, NEW FITTING WAS TREATED AND PAINTED IAW SRM 51-10-3, PAR 14 AND 21, NEW FITTING WAS INSTALLED IAW SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON FITTING AT BS 905 X -51 AND Z -2. ADJUSTED AND DRILLED NEW FITTING IAW DWG 3922286, REV D, SRM 51-10-4, NEW FITTING WAS TREATED AND PAINTED IAW SRM 51-10-3, PAR 14 AND 21, NEW FITTING WAS INSTALLED IAW SRM 51-30-5.