What was found
CRACKED FRAME ANGLE BS 1452 BETWEEN LONGERONS 2 & 3L. A NEW FRAME ANGLE WAS FABRICATED AND INSTALLED IAW DWG 9911860, REV C, SRM 51-30-2, AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FRAME ANGLE BS 1452 BETWEEN LONGERONS 2 & 3L. A NEW FRAME ANGLE WAS FABRICATED AND INSTALLED IAW DWG 9911860, REV C, SRM 51-30-2, AND 51-10-2.