What was found
LIGHTINING STRIKE DAMAGE AT FS 529 BETWEEN STR 29L AND 28L. BLENDED AREA IAW SRM 53-00-01, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED AREA IAW SRM 53- 00-01, REPAIR NR 2. REMOVED FASTENERS COMMON TO REPAIR IAW SRM 53-00-01, REPAIR NR 2. C/W EDDY CURRENT INSPECTION OF CUTOUT AND COMMON FASTENERS HOLES IAW SRM 53-00-01, REPAIR NR 2, STEPS 4 AND 5. FABRICATED REPAIR PARTS IAW SRM 53-00-01. REPAIR NR 2. OK TO INSTALL REPAIR QC1509. INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 53-00-01, REPAIR NR 2. CATEGORY B REPAIR INSPECTION REQUIREMENTS INSPECTION THRESHOLD. REMOVED LFEC FROM MASK ATTACHED INSPECTION ADDED TIME.