What was found
CORROSION ON LT AND RT ANGLE FWD, MID, AND AFT SECTION AT STAIRWAY WALKING BRIDGE. ANGLES WERE BLENDED AND TREATED AND PAINTED IAW SRM 51-10-3, PAR 14, 21, AND 26. AREA WAS OUT OF LIMITS AND WAS REPAIRED IAW SRM 53-01, FIG 4, TRANS: V260-RM. EQ GAGE THICKNESS 35DL. ORIGINAL THICKNESS IS .032" MIN, REMAINING THICKNESS IS 0.022", ASSOCIATED ER/A 00-511165, ADDED FOR AC 0906.