What was found
CORROSION ON CORNER FITTING FRAME 20 AT LEVEL STR 23L AT FWD GALLEY AREA. REPLACED CORNER FITTING LOCATED AT FRAME 20 AT LEVEL OF STR 23L IN FORWARD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112225.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON CORNER FITTING FRAME 20 AT LEVEL STR 23L AT FWD GALLEY AREA. REPLACED CORNER FITTING LOCATED AT FRAME 20 AT LEVEL OF STR 23L IN FORWARD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112225.