What was found
DENT ON FWD CARGO LT FRAME AT BS 780 JUST ABOVE STR 24L. DENT ON FWD CARGO LT FRAME AT BS 780, STR 24L, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG 101. TRIMMED OUT DENT L= 1", W=1"X 0.5" R IAW FIG 201, DETAIL III, REPAIR 5. FORMED J-SECTION REPAIR IAW SRM 53-00-07, FIG 201, REPAIR 5, PG 201. INSTALLED J-SECTION REPAIR AT LT BS 780, ABOVE STR 24L IAW SRM 51-40-02, PG 6-7 AND SRM 53-00-07, REPAIR 5. REPAIR IS PERMANENT CAT"B" WITH THRESHOLD INSPECTION TO START AT 50000, F/C & REPEAT INSPECTION EVERY 12000 F/C THEREAFTER USING HFEC & DETAILED INSPECTION. ACFT IS CURRENTLY AT 16474, F/C REF SRM 53-00-07, FIG 201 REPAIR 5, TABLE II.