What was found
PUNCTURE ON CUSP WEB BS 1129 AND X -54 DAMAGE AREA WAS REMOVED, NEW FILLER AND DOUBLER WERE FABRICATED, NEW FILLER AND DOUBLER WERE TREATED AND PAINTED, NEW DOUBLER AND FILLER WERE INSTALLED IAW SRM 53-05, FIG 131A-19 AND 51-10-3, PAR 14 AND 21.