What was found
WHILE PERFORMING OVERWING FRAME INSPECTION AT BS 737. FOUND FLOORBEAM CRACKED THRU UPPER RADIUS. REPLACED FLOORBEAM IAW DWG 5940863-18599. REQUIRED INSPECTION COMPLETED.