What was found
CORROSION ON CUSP WEB BS 237 BETWEEN X=-54 / X=-60. DAMAGE WAS REMOVED TO REPAIR THE DAMAGED AREA IAW SRM 53-05. THEN, THE TRIM WAS INSPECTED FOR CRACKS AND NO CRACKS WERE FOUND. AFTER THAT, REPAIR PARTS WERE FABRICATED IAW SRM 53-05, FIG 131A-10 TO BE TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14 THEN REPAIR PARTS WERE INSTALLED IAW SRM 51-30-2. FINALLY FITTING AND SEAT TRACK WERE INSTALLED IAW SRM 51-30-1 AND 51-30-5. CIC WILL BE APPLIED WITH THE NRC 20000072167, CARD 18, ACFT ZONE 201.