What was found
CORROSION FOUND ON FLOOR SUPPORT 1155 BETWEEN LONGERON 28 -29R ABOVE DOOR FRAME WEB. CORROSION WAS REMOVED IAW SRM 51-10-3 PAR. 21, 14, 26, 38 AND FOUND OUT LIMITS AND WAS REPLACED IAW DWG 5936660, REV B2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLOOR SUPPORT 1155 BETWEEN LONGERON 28 -29R ABOVE DOOR FRAME WEB. CORROSION WAS REMOVED IAW SRM 51-10-3 PAR. 21, 14, 26, 38 AND FOUND OUT LIMITS AND WAS REPLACED IAW DWG 5936660, REV B2.