What was found
CRACK FOUND ON CUSP WEB BETWEEN BS 903 - 916, BETWEEN X -50 AND X -60. WEB WAS REMOVED. CRACK WAS STOPPED, REPAIR IN CUSP WEB WITH DOUBLER AND FILLER WERE FABRICATED, TREATED, PAINTED AND INSTALLED IAW SRM 51-30-5, 53-01 FIG 2, 53-05, FIG 131A, 51-10-3 FOR 14 AND 21 AND 51-30-2 LONGERON CRACK 2.500". REPAIR CUSP WEB BS=Y903 TO Y= 904 WILL BE ATTENDED NRCS 20000077571 AND CARD 291, ZONE 201 AND REPAIR WAS ACCOMPLISHED FROM STA Y=905 TO Y=916. BETWEEN X=-50 AND X=-60.