What was found
MAIN CABIN-CORROSION ON RT INNER CREASE CHORD BETWEEN BS 729.6 AND BS 740, RBL 65. REMOVED CORROSION AT RT INNER CREASE BEAM BETWEEN BS 729-740, RBL 65, MATERIAL ORIGINAL THICKNESS .080", MATERIAL LOSS .051", FOUND OUT OF LIMITS IAW SRM 53-60-13, FIG 101, DETAIL III ALLOWABLE DAMAGE 1, W=0.50", L=0.50", D=0.051". R & R RT INNER CREASE BEAM CHORD FROM BS 664-, BS 756, RBL 65 IAW SRM 51-40-02, FIG 4, PG 20, PG 6. PARA 7.D AND DWG 143N8322.