What was found
LIGHTNING STRIKE AT BS 402, 5" BELOW STR 11R. DRILLED DAMAGED RIVET AND INSTALLED BLIND FASTNER IAW R1 AND 539190-14. NEEDS REPEAT INSP AT 500 CYCLE INTERVALS AND SOLI FASTENER INSTALLED NO LATER THAN 3000 CYCLES/24 MONTHS. ERA 539314-14, SECT IV 1 TIME INSPECTION IS REQUIRED NTE 30S AFTER SECT I. C/W INSP IAW ERA 539314-14, SEC 2, REV ORIGINAL, NO FURTHER DEFECTS NOTED.