What was found
CRACK ON RT CABIN FLOOR CUSP WEB BETWEEN BS 789-807 AND X -54 TO -60. A NEW CUSP WEB AND RINGS DOUBLER WERE TREATED, PAINTED, FABRICATED AND INSTALLED IAW SRM 53-05, FIG 131A-6, 51-10-3 PAR. 14, 21, 51-30-2, 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON RT CABIN FLOOR CUSP WEB BETWEEN BS 789-807 AND X -54 TO -60. A NEW CUSP WEB AND RINGS DOUBLER WERE TREATED, PAINTED, FABRICATED AND INSTALLED IAW SRM 53-05, FIG 131A-6, 51-10-3 PAR. 14, 21, 51-30-2, 51-30-5.