What was found
RIGHT WING INBD MAIN FLAP T/E PANEL PUNCTURED ON BOTTOM 52" FROM INBD END 4" FROM FWD END. REMOVED ALL CONTAMINATION AND WATER FROM DAMAGED AREA IAW SRM 51-70-06 PARA 5.C.2. REMOVED DAMAGE WITH 2" DIAMETER AND PREPARED AREA FOR REPAIR IAW SRM 51-70-06 PARA 5.C.3. FABRICATED HONEYCOMB REPLACEMENT CORE AND INSTALLED IAW SRM 51-70-06 PARA 5.C.4. PREPARED AND APPLY REPAIR PLIES TO REPAIR AREA IAW SRM 51-70-06, PARA 5.C.6. APPLIED PRIMER AND TOPCOAT TO REPAIR AREA IAW AMM 51-21-10-377-039, PARA C.1.