What was found
ON OK TO CLOSE FLOOR PANELS IN FWD CABIN, FOUND STABILIZATION STRAP CRACKED AND SEVERED AT BS 377, LBL-45. REMOVED DAMAGE AREA AT BS 377, LBL 45 IAW SRM 53-00-51, REPAIR 12. CUT OUT LENGTH, L=1.88" FINAL, ACCOMPLISHED HFEC AND OPEN HOLE INSP. NO DAMAGE NOTED, FABRICATED REPAIR PARTS IAW SRM 53-00-51, REP 12. TABLE 201, TREATED AND PRIMED REPAIR PARTS IAW SRM 51-20-01, PAGE 6 AND 26N, AND INSTALLED REPAIR PARTS AT BS 377, LBL 45 IAW SRM 53-00-51, REPAIR 12 INSTALLED ID TAG IAW TOPP 30-10-70, PG 13.