What was found
FWD CARGO BS 660 STR 23-25L, FRAME DENTED SEVERAL PLACES. REPAIRED FWD CARGO FRAME AT STA 660, STR 23L-25L BY INSTALLING. REPAIR DOUBLER ON FRAME AT BS 660 BETWEEN STR 22L- 26L, REF SRM 53-00-07, REPAIR 5, FIG 201, PG 208, TRIMOUT 4 EA ON FRAME: 1.140" X 1.040" X 0.5"R, 1.140" X 1.040" X 0.5"R, 1.140" X 1.040" X 0.5" R, 4.140" X 1.040" X 0.5" R. REPAIR IS PERMANENT CAT "B" ON ZONE 2 WITH THRESHOLD INSPECTION TO START AT OR BEFORE 42657 F/C & REPEAT INSPECTION EVERY 11000 F/C. THEREAFTER USING, HFEC, HIGH FREQUENCY EDDY CURRENT & DETAILED INSPECTION IN REF SRM 53-00-07, REPAIR 5, FIG 201, TABLE II, PAGE 210. ACFT IS CURRENTLY AT 17657 F/C.