What was found
RT SIDE FWD FUSELAGE BELOW AND AFT OF RT AOA VANE HAS A DENT. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01, REPAIR 2, FIGURE 201. C/W HFEC INSPECTION IAW SRM 53-00-01 REPAIR 3, FIG 201 WITH NO ITEMS NOTED. FABRICATED REPAIR PARTS IAW SRM 53-00-01, REPAIR 2, FIG 201. OK TO INSTALL REPAIR DOUBLER. INST REPAIR IAW SRM 53-00-01, REP 2, FIG 201 AT FS 247 AT STR 22R. REPAIR IS CONSIDERED CATEGORY "B" W/ AN INSPECTION THRESHOLD OF 37.5K FLT CYCLES, REPEAT INSPECTION ALTERNATIVE OF HFEC AT AN INTERVAL OF 6K FLT CYCLES REF NDT PART 6, 51-00-01. THIS IS ALL IAW 53-00-01 SRM REPAIR 2, FIG 201. INSTALLATION OF REPAIR INSPECTED. RII COMPLETE.