What was found
CORROSION OUT LIMITS ON LT CUSP WEB X=54 TO 60 BETWEEN BS 845 TO 864 AT PAX CABIN FLOOR STRUCTURE. CUSP WEB WAS REPAIRED IAW SRM 53-05, FIG 53-05, FIG 131A-14, 51-10-3 PAR 14, 21 AND 38, SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION OUT LIMITS ON LT CUSP WEB X=54 TO 60 BETWEEN BS 845 TO 864 AT PAX CABIN FLOOR STRUCTURE. CUSP WEB WAS REPAIRED IAW SRM 53-05, FIG 53-05, FIG 131A-14, 51-10-3 PAR 14, 21 AND 38, SRM 51-30-2.