What was found
CORROSION OUT LIMITS ON RT CUSP WEB BETWEEN RBL 54 TO 60 BS 1045 AT PAX CABIN FLOOR STRUCTURE. AREA OUT LIMITS WAS REPAIRED IAW SRM 53-05, FIG 131A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.