What was found
CORROSION ON RT CUSP WEB MEMBRANE FROM BS 440 TO 503 UPPER AND LOWER SURFACES INCLUDING REPAIR DOUBLERS AT PAX CABIN BETWEEN X=-54 TO X=-60. AREA OUT OF LIMITS WAS ATTENDED IAW SRM 51-30-1, 51-30-2, 51-30-5, 51-30-3 PARR. 14, 21, 26, 53-05, FIG 131A-11.