What was found
A CORROSION AROUND BORE INBD FACE OF RT MLG RETRACT ACTUATOR SUPPORT FITTING. CORROSION ON BOTH FACE OF BORE WAS REMOVED WITH A INITIAL MEASURE OF 1.237" AND A FINAL MEASURE AFTER REWORK OF 1.230". WITHIN LIMITS IAW DWG 5935812, REV BB FPI WAS PERFORMED AND REWORKED AREA WAS TREATED IAW SRM 51-10-3, PAR 21.