What was found
CORROSION, OUT LIMITS, ON RT CUSP WEB BETWEEN BS X=-54 TO -60 BS 484 - 503 AT PAX CABIN FLOOR STRUCTURE. DAMAGE WAS REMOVED, REPAIR PARTS WERE FABRICATED, REPAIR PARTS WERE TREATED AND PAINTED, REPAIRED PARTS WERE INSTALLED, CIC WAS APPLIED IAW SRM 53-05, FIG 131A-7, 51-10-3, PAR 14, 21 AND 38, 51-30-2.