CORROSION ON LOWER SILL LT AT AFT GALLEY AREA . REPLACED LOWER SILL LOCATED BETWEEN FRAME 66 TO FRAME 68 AT LEVEL STR 23 LT SIDE AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.