What was found
FASTENER ON EDGE OF LIGHTING HOLE ON RT CUSP WEB PREVIOUS REPAIR BETWEEN BS 712 TO 720. PREVIOUS REPAIR DOUBLER WAS REMOVED IAW SRM 51-30-5 FITTING WAS REMOVED, DAMAGE WAS REMOVED, HFEC INSPECTION WAS PERFORMED AND NO CRACKS WERE FOUND, REPAIR DOUBLER WAS FABRICATED, TREATED AND PAINTED IAW SRM 53-05, FIG 131, 51-10-3 PAR 21, 14. REPAIR PARTS WERE INSTALLED IAW SRM 51-30-2. FITTING WAS INSTALLED IAW SRM 51-30-1. CIC WAS APPLIED IAW SRM 51-10-3, PAR 38.