What was found
CRACK ON CUSP WEB BS 223 BETWEEN X 54 - 60. DAMAGE WAS REMOVED IAW SRM 53-05, FIG 131A-6. REPAIR FABRICATED IAW SRM 53-05, FIG 131A-6. AREA AND REPAIR TREATED, PAINTED IAW SRM 51-10-3, PAR 14 AND 21. REPAIR INSTALLED IAW SRM 53-05, FIG 131A-6.