What was found
CORROSION ON LT CUSP WEB BS 1248, BETWEEN X=50 TO X=60 AT CABIN FLOOR STRUCTURE. SEAT TRACK WAS REMOVED DAMAGE ON CUSP WEB WAS REMOVED, PARTS FOR REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-05, FIG 131A-14 AND SEAT TRACK WAS INSTALLED IAW SRM 51-30-5.