What was found
FWD CARGO BS 660 STR 23-25R, FRAME DENTED 2 PLACES. TRIMMED-OUT 2 EA DENTS ON FRAME AT BS 660, STR 23R-25R, REF SRM 53-00-07, REPAIR 5. TRIMOUT NR 1 MEASURES 1.040" X 2.105" X 0.5" R, TRIMOUT NR 2 MEASURES 1.090" X 1.040" X 0.5"R. ACCOMPLISHED PERMANENT REPAIR CAT "B" ON FRAME 660 BS, STR 23R -25R, REF SRM 53-00-07, REPAIR 5. THRESHOLD INSPECTION REQUIRED AT 42657 F/C WITH REPEAT INSPECTION EVERY 11000 F/C THEREAFTER USING HFEC & DETAILED INSPECTION. ACFT CURRENTLY AT 17657, F/C REF SRM 53-00-07, REP 5, FIG 201, TABLE II, PAGE 210. ACCOMPLISHED ER/A 539824-14, REV ORIGINAL FOR 2 EA STR CLIPS, R & R AT STA 660, BETWEEN STR 23R-25R.