What was found
NR 2 FLAP TRACK, AFT MOUNT SHIM AREA HAS CORROSION COMING OUT FROM MATING SURFACES. REMOVED AND INSTALLED NR 2 FLAP TRACK REF AMM 27-51-15. REPAIRED FLAP TRACK UPPER MOUNT PAD IAW CMM 27-51-82. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0064:2751-2540-LT/003 00157. REMOVED AND INSTALLED NR 2 FLAP TRACK REF AMM 27-51-15, REPAIRED FLAP TRACK UPPER MOUNT PAD IAW CMM 27-51-82. CLOSING REQUIREMENTS RII: INSPECTOR. CORROSION LEVEL CHANGED FROM: N TO: 1.