What was found
CORROSION ON SEAT TRACK -Y1292 BETWEEN FRAME 12 TO FRAME 24 MEASURES APPROXIMATELY L=1", W=0.200", D=0.002" AT FWD GALLEY AREA. REPLACED SEAT TRACK -Y1292 LOCATED BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWGS NR D53112812, D53110984 AND D53110920. TOOK MEASURE OF CORROSION ARE: P1, UPPER FLANGE L=27", W=0.353" AND D=0.070", P2, LATERAL FLANGE L=22", W=0.991" AND D=0.075.