What was found
2 EA DENTS ON FWD CARGO LT FRAME UPPER FLANGE AT BS 600 BETWEEN STR 23L-25L. REPAIRED FWD CARGO LT FRAME UPPER FLANGE AT BS 600 BETWEEN STR 23L AND STR 25L IAW DWG 143N1009 AND SRM 53-00-07, FIG 201, PAGE 201. TRIMOUTS, 2 EA, MEASURE NR 1: 1.54" X 0.94" X 0.5"R, NR 2: 1.49" X 0.94" X 0.5"R. REPAIR IS PERMANENT CAT "B" ON ZONE 2 WITH THRESHOLD INSPECTION TO START AT OR BEFORE 42053 F/C & REPEAT INSPECTION EVERY 11000 F/C THEREAFTER USING HFEC & DETAILED INSPECTION . ACFT IS CURRENTLY AT 17053, FC REF SRM 53-00-07, FIG 201, REPAIR 5, TABLE II, PAGE 210.