As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 2 SLAT HAS NUMEROUS UNIDENTIFIED DENTS SLAT UPPER T/E WEDGE. INSPECTED NR 2 SLAT FOUND NUMEROUS DENTS ALL ARE IN LIMITS OF SRM 57-43-02. TAP AND DELAMATION TEST C/W ON RC 56-0557-8-0072. NR 2 SLAT NEEDS TO BE ADDED TO MONTOR INSPECTION INSTALLED ID TAG ON NR 2 SLAT DAMAGED AREA.